Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
ACS Nano ; 18(1): 972-982, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38117550

RESUMO

The ability to efficiently absorb light in ultrathin (subwavelength) layers is essential for modern electro-optic devices, including detectors, sensors, and nonlinear modulators. Tailoring these ultrathin films' spectral, spatial, and polarimetric properties is highly desirable for many, if not all, of the above applications. Doing so, however, often requires costly lithographic techniques or exotic materials, limiting scalability. Here we propose, demonstrate, and analyze a mid-infrared absorber architecture leveraging monolayer films of nanoplasmonic colloidal tin-doped indium oxide nanocrystals (ITO NCs). We fabricate a series of ITO NC monolayer films using the liquid-air interface method; by synthetically varying the Sn dopant concentration in the NCs, we achieve spectrally selective perfect absorption tunable between wavelengths of two and five micrometers. We achieve monolayer thickness-controlled coupling strength tuning by varying NC size, allowing access to different coupling regimes. Furthermore, we synthesize a bilayer film that enables broadband absorption covering the entire midwave IR region (λ = 3-5 µm). We demonstrate a scalable platform, with perfect absorption in monolayer films only hundredths of a wavelength in thickness, enabling strong light-matter interaction, with potential applications for molecular detection and ultrafast nonlinear optical applications.

2.
ACS Nano ; 17(23): 23649-23658, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38039345

RESUMO

The high explosiveness of hydrogen gas in the air necessitates prompt detection in settings where hydrogen is used. For this reason, hydrogen sensors are required to offer rapid detection and possess superior sensing characteristics in terms of measurement range, linearity, selectivity, lifetime, and environment insensitivity according to the publicized protocol. However, previous approaches have only partially achieved the standardized requirements and have been limited in their capability to develop reliable materials for spatially accessible systems. Here, an electrical hydrogen sensor with an ultrafast response (∼0.6 s) satisfying all demands for hydrogen detection is demonstrated. Tailoring structural engineering based on the reaction kinetics of hydrogen and palladium, an optimized heating architecture that thermally activates fully suspended palladium (Pd) nanowires at a uniform temperature is designed. The developed Pd nanostructure, at a designated temperature distribution, rapidly reacts with hydrogen, enabling a hysteresis-free response from 0.1% to 10% and durable characteristics in mechanical shock and repetitive operation (>10,000 cycles). Moreover, the device selectively detects hydrogen without performance degradation in humid or carbon-based interfering gas circumstances. Finally, to verify spatial accessibility, the wireless hydrogen detection system has been demonstrated, detecting and reporting hydrogen leakage in real-time within just 1 s.

3.
PLoS One ; 18(11): e0294554, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37983215

RESUMO

Numerous studies make extensive use of healthcare data, including human materials and clinical information, and acknowledge its significance. However, limitations in data collection methods can impact the quality of healthcare data obtained from multiple institutions. In order to secure high-quality data related to human materials, research focused on data quality is necessary. This study validated the quality of data collected in 2020 from 16 institutions constituting the Korea Biobank Network using 104 validation rules. The validation rules were developed based on the DQ4HEALTH model and were divided into four dimensions: completeness, validity, accuracy, and uniqueness. Korea Biobank Network collects and manages human materials and clinical information from multiple biobanks, and is in the process of developing a common data model for data integration. The results of the data quality verification revealed an error rate of 0.74%. Furthermore, an analysis of the data from each institution was performed to examine the relationship between the institution's characteristics and error count. The results from a chi-square test indicated that there was an independent correlation between each institution and its error count. To confirm this correlation between error counts and the characteristics of each institution, a correlation analysis was conducted. The results, shown in a graph, revealed the relationship between factors that had high correlation coefficients and the error count. The findings suggest that the data quality was impacted by biases in the evaluation system, including the institution's IT environment, infrastructure, and the number of collected samples. These results highlight the need to consider the scalability of research quality when evaluating clinical epidemiological information linked to human materials in future validation studies of data quality.


Assuntos
Bancos de Espécimes Biológicos , Confiabilidade dos Dados , Humanos , Manejo de Espécimes/métodos , Atenção à Saúde , República da Coreia
4.
J Vet Med Sci ; 85(10): 1116-1120, 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37661431

RESUMO

A 15-year-old, spayed female, Scottish Straight cat without any traumatic history was presented with swollen abdomen and diagnosed as an abdominal wall hernia. Abdominal ultrasound revealed thickened, irregular, and hypoechoic change of abdominal wall muscle adjacent to defect. During the herniorrhaphy, multiple nodules were identified in the subcutaneous tissue around the defect. Histological examination of the nodular tissue was performed, and it was confirmed as mammary gland tumor. After the surgery, metastatic changes of the pancreas were identified, and pleural effusion and ascites were also confirmed. The patient deteriorated rapidly and died 78 days after the surgery. This is the first case presenting abdominal wall hernia induced by malignant tumor in veterinary medicine.


Assuntos
Parede Abdominal , Carcinoma , Doenças do Gato , Hérnia Abdominal , Hérnia Ventral , Glândulas Mamárias Humanas , Gatos , Animais , Feminino , Humanos , Hérnia Abdominal/diagnóstico por imagem , Hérnia Abdominal/cirurgia , Hérnia Abdominal/veterinária , Hérnia Ventral/cirurgia , Hérnia Ventral/veterinária , Parede Abdominal/cirurgia , Herniorrafia/veterinária , Carcinoma/cirurgia , Carcinoma/veterinária , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/cirurgia
5.
Nano Lett ; 23(16): 7633-7641, 2023 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-37558214

RESUMO

Assembling plasmonic nanocrystals in regular superlattices can produce effective optical properties not found in homogeneous materials. However, the range of these metamaterial properties is limited when a single nanocrystal composition is selected for the constituent meta-atoms. Here, we show how continuously varying doping at two length scales, the atomic and nanocrystal scales, enables tuning of both the frequency and bandwidth of the collective plasmon resonance in nanocrystal-based metasurfaces, while these features are inextricably linked in single-component superlattices. Varying the mixing ratio of indium tin oxide nanocrystals with different dopant concentrations, we use large-scale simulations to predict the emergence of a broad infrared spectral region with near-zero permittivity. Experimentally, tunable reflectance and absorption bands are observed, owing to in- and out-of-plane collective resonances. These spectral features and the predicted strong near-field enhancement establish this multiscale doping strategy as a powerful new approach to designing metamaterials for optical applications.

6.
Polymers (Basel) ; 15(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37242888

RESUMO

Tendons are responsible for transmitting mechanical forces from muscles to bones for body locomotion and joint stability. However, tendons are frequently damaged with high mechanical forces. Various methods have been utilized for repairing damaged tendons, including sutures, soft tissue anchors, and biological grafts. However, tendons experience a higher rate of retear post-surgery due to their low cellularity and vascularity. Surgically sutured tendons are vulnerable to reinjury due to their inferior functionality when compared with native tendons. Surgical treatment using biological grafts also has complications such as joint stiffness, re-rupture, and donor-site morbidity. Therefore, current research is focused on developing novel materials that can facilitate the regeneration of tendons with histological and mechanical characteristics similar to those of intact tendons. With respect to the complications in association with the surgical treatment of tendon injuries, electrospinning may be an alternative for tendon tissue engineering. Electrospinning is an effective method for fabrication of polymeric fibers with diameters ranging from nanometers to micrometers. Thus, this method produces nanofibrous membranes with an extremely high surface area-to-volume ratio, which is similar to the extracellular matrix structure, making them suitable candidates for application in tissue engineering. Moreover, it is possible to fabricate nanofibers with specific orientations that are similar to those of the native tendon tissue using an adequate collector. To increase the hydrophilicity of the electrospun nanofibers, natural polymers in addition to synthetic polymers are used concurrently. Therefore, in this study, aligned nanofibers composed of poly-d,l-lactide-co-glycolide (PLGA) and small intestine submucosa (SIS) were fabricated using electrospinning with rotating mandrel. The diameter of aligned PLGA/SIS nanofibers was 568.44 ± 135.594 nm, which closely resembles that of native collagen fibrils. Compared to the results of the control group, the mechanical strength exhibited by the aligned nanofibers was anisotropic in terms of break strain, ultimate tensile strength, and elastic modulus. Elongated cellular behavior was observed in the aligned PLGA/SIS nanofibers using confocal laser scanning microscopy, indicating that the aligned nanofibers were highly effective with regard to tendon tissue engineering. In conclusion, considering its mechanical properties and cellular behavior, aligned PLGA/SIS is a promising candidate for tendon tissue engineering.

7.
Nano Lett ; 23(7): 3030-3037, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-36989531

RESUMO

Optical properties of nanoparticle assemblies reflect distinctive characteristics of their building blocks and spatial organization, giving rise to emergent phenomena. Integrated experimental and computational studies have established design principles connecting the structure to properties for assembled clusters and superlattices. However, conventional electromagnetic simulations are too computationally expensive to treat more complex assemblies. Here we establish a fast, materials agnostic method to simulate the optical response of large nanoparticle assemblies incorporating both structural and compositional complexity. This many-bodied, mutual polarization method resolves limitations of established approaches, achieving rapid, accurate convergence for configurations including thousands of nanoparticles, with some overlapping. We demonstrate these capabilities by reproducing experimental trends and uncovering far- and near-field mechanisms governing the optical response of plasmonic semiconductor nanocrystal assemblies including structurally complex gel networks and compositionally complex mixed binary superlattices. This broadly applicable framework will facilitate the design of complex, hierarchically structured, and dynamic assemblies for desired optical characteristics.

8.
Front Vet Sci ; 10: 1323088, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38169649

RESUMO

A 6-year-old castrated, mixed breed cat presented with vomiting, anorexia, and lethargy. Ultrasonography and computed tomography revealed a round, well-marginated structure closely associated with the ileum proximal to the ileocolic junction. Exploratory laparotomy revealed a mass originating from the distal end of the ileum, close to the ileocolic junction. The mass did not interact with the intestinal lumen. Excisional biopsy with omentalization was performed without small intestinal resection to preserve the ileocolic junctions. Histopathological examination confirmed the presence of an enteric duplication cyst. The cat recovered uneventfully from surgery and remained asymptomatic postoperatively. No recurrence was identified 4 months after surgery. Enteric duplication cysts are uncommon congenital anomalies that originate in the gastrointestinal tract. They could either be communicating or non-communicating with the intestinal lumen. Enteric duplication cysts can be symptomatic or asymptomatic. Enteric duplication cysts associated with the esophagus, duodenum, and jejunum have also been reported in cats. However, to the best of our knowledge, this is the first reported case of an enteric duplication cyst in the feline ileum. Thus, enteric duplication should be considered a differential diagnosis in cystic masses of the ileum.

9.
Vet Sci ; 9(12)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36548841

RESUMO

An 11-year-old castrated male Shih Tzu was referred for lethargy and melena. The hematocrit level was 18.8% (normal range: 36-56%), indicating severe anemia. Abdominal ultrasound revealed a round-to-oval-shaped mass in the stomach. Computed tomography (CT) revealed an intraluminal mass (17 × 12 × 15 mm) cranial to the pyloric antrum. After obtaining informed consent from the owner, exploratory laparotomy and subsequent gastrostomy were performed, showing an ulcerated mass potentially responsible for the severe anemia. A lump of hair was firmly attached to the ulcerated surface of the mass. After complete removal of the mass, the anemia resolved spontaneously. Histological examination revealed that the mass was a gastric hyperplastic polyp. At the 6-month follow-up, the dog was healthy with a normal hematocrit level. Gastric hyperplastic polyps are tumor-like lesions arising from the mucosal surface of the stomach, and projecting into the lumen. They can appear in any part of the stomach, and are usually found incidentally during gastric endoscopy or necropsy. The clinical signs include chronic occult blood loss, abdominal pain, and gastric tract obstruction. Gastric polyps causing acute blood loss anemia have rarely been reported in human medicine. To our knowledge, this is the first report describing a gastric hyperplastic polyp that caused severe anemia because of acute blood loss in a dog.

10.
J Am Chem Soc ; 144(50): 22941-22949, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36472892

RESUMO

Crystallographic defects are essential to the functional properties of semiconductors, controlling everything from conductivity to optical properties and catalytic activity. In nanocrystals, too, defect engineering with extrinsic dopants has been fruitful. Although intrinsic defects like vacancies can be equally useful, synthetic strategies for controlling their generation are comparatively underdeveloped. Here, we show that intrinsic defect concentration can be tuned during the synthesis of colloidal metal oxide nanocrystals by the addition of metal salts. Although not incorporated in the nanocrystals, the metal salts dissociate at high temperatures, promoting the dissociation of carboxylate ligands from metal precursors, leading to the introduction of oxygen vacancies. For example, the concentration of oxygen vacancies can be controlled up to 9% in indium oxide nanocrystals. This method is broadly applicable as we demonstrate by generating intrinsic defects in metal oxide nanocrystals of various morphologies and compositions.


Assuntos
Nanopartículas Metálicas , Sais , Óxidos , Metais , Oxigênio
11.
Sci Rep ; 12(1): 22401, 2022 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-36575249

RESUMO

Urban climate influences economic activities and the health and safety of urban residents. Therefore, monitoring temperature in urban areas is important. However, owing to the lack of space for an appropriate observation site, an automatic weather station (AWS) was installed on a building rooftop. The rooftop installation can indicate temperature differences depending on the intensity of strong solar radiation and radiant heat of the building, and wind speed. Therefore, in this study, we aimed to provide observation standards for measuring rooftop temperature according to the optimal rooftop material and observation height. Specifically, an AWS was installed on the rooftop of the Gochang Standard Weather Station (GSWO), Jeollabuk-do Province, to observe the urban climate in South Korea and establish suitable weather standards. Different temperatures, optimum surface materials, and optimum heights for measuring the temperature at the rooftop of GSWO were investigated and compared over 1 year. The temperature recorded after installing a palm mat on the rooftop was more similar to that observed in the grassland. Furthermore, the installation height of the temperature sensor of 2.5-3.0 m for the palm mat and 3.5-4.0 m for concrete was found to be the optimal height for observing temperature at the rooftop.


Assuntos
Clima , Tempo (Meteorologia) , Temperatura , Vento , República da Coreia , Temperatura Alta , Monitoramento Ambiental
12.
Vet Sci ; 9(11)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36356071

RESUMO

A 7-year-old spayed female domestic shorthair cat presented with a swollen right forelimb and mild lameness. On physical examination, the mass was palpable in the right humeral region, and the cat exhibited pain on palpation. Radiography revealed an expansile osteolytic lesion at the proximal end of the right humerus. Computed tomography (CT) revealed an expansile bony mass on the proximal end of the right humerus and a mild periosteal reaction around the acromion of the scapula. Amputation of the right forelimb, including the scapula and removal of the axillary lymph node, were strongly recommended to the owner, but were declined. Four months after the initial presentation, the cat presented with a dramatically swollen right forelimb and progressive lameness. CT was performed again. In addition to osteolytic changes in the mass, vascular development had occurred at the cranioproximal region. The right forelimb, including the scapula and ipsilateral lymph nodes, was removed. The cat died during the postoperative recovery period. Based on clinical, diagnostic imaging, and histological findings, the final diagnosis was aneurysmal bone cyst. To the best of our knowledge, this is the first case of an aneurysmal bone cyst in the humerus of a cat.

13.
Sensors (Basel) ; 22(19)2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36236667

RESUMO

This paper presents a fast design optimization using an effective characteristic analysis for linear permanent magnet motors (LPMMs) with techniques for improving motor performance such as using an auxiliary tooth, permanent magnet (PM) skew, and overhang structures. These techniques have different effects on the characteristics of the LPMM depending on the combinations of each other, resulting in complexity in the design optimization process. In particular, the three-dimensional (3-D) effect of the PM skew and overhang structure takes a lot of time to be analyzed. To deal with this problem, an effective magnetic field analysis method and a novel optimization algorithm are proposed. Preferentially, the field reconstruction method is used for a fast and accurate evaluation of the magnetic field of the LPMM. In the proposed magnetic field analysis method, the change of magnetic field distribution due to the addition of an auxiliary tooth is predicted, and the 3-D magnetic field effect of PM skew and overhang structure is considered. By reducing the computational burden in the magnetic field analysis, the electromagnetic characteristics of LPMMs can be calculated quickly, such as detent force, end force, thrust force, and back-EMF. The effect of the auxiliary tooth and overhang structure on the optimal PM skew length is investigated with comparative study results. Subsequently, the proposed optimization algorithm has the advantage of reducing time cost by providing multimodal optimization and robustness evaluation of local peaks at the same time. The proposed method is verified via comparison with finite element analysis and experimental results.


Assuntos
Algoritmos , Imãs , Fenômenos Eletromagnéticos , Análise de Elementos Finitos , Campos Magnéticos
14.
ACS Nano ; 16(8): 11957-11967, 2022 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-35621510

RESUMO

Palladium (Pd) has been drawing increasing attention as a hydrogen (H2) detecting material due to its highly selective sensitivity to H2. However, at H2 concentrations above 2%, Pd undergoes an inevitable phase transition, causing undesirable electrical and mechanical alterations. In particular, nonlinear gas response (ΔR/R0) that accompanies phase transition has been a great bottleneck for detecting H2 in high concentrations, which is especially important as there is a risk of explosion over 4% H2. Here, we propose a phase-transition-inhibited Pd nanowire H2 sensor that can detect up to 4% H2 with high linearity and high sensitivity. Based on the calculation of the change in free energy, we designed Pd nanowires that are highly adhered to the substrate to withstand the stress that leads to phase transition. We theoretically optimized the Pd nanowire dimensions using a finite element method simulation and then experimentally fabricated the proposed sensor by exploiting a developed nanofabrication method. The proposed sensor exhibits a high sensing linearity (98.9%) with high and stable sensitivity (ΔR/R0/[H2] = 875%·bar-1) over a full range of H2 concentrations (0.1-4%). Using the fabricated Pd sensors, we have successfully demonstrated a wireless sensor module that can detect H2 with high linearity, notifying real-time H2 leakage through remote communication. Overall, our work suggests a nanostructuring strategy for detecting H2 with a phase-transition-inhibited pure Pd H2 sensor with rigorous scientific exploration.

15.
J Vet Med Sci ; 83(11): 1670-1673, 2021 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-34526413

RESUMO

A 3-year-old male domestic shorthair cat presented with sudden ataxia. Neurologic examination showed complete loss of proprioception in the thoracic and pelvic limbs. Computed tomography and magnetic resonance imaging revealed a non-metallic foreign body penetrating the spinal cord. The foreign body was removed by the ventral approach to the atlanto-occipital junction. Mild improvement of proprioception was observed the day after surgery. In a follow-up two months after surgery, the owner reported a complete recovery of the patient, showing a normal gait. To the author's knowledge, this is the first case report describing successful removal of an intramedullary foreign body penetrating cervical spinal cord by ventral approach in a cat.


Assuntos
Doenças do Gato , Corpos Estranhos , Animais , Gatos , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia , Corpos Estranhos/veterinária , Imageamento por Ressonância Magnética/veterinária , Masculino , Medula Espinal/diagnóstico por imagem , Medula Espinal/cirurgia , Tomografia Computadorizada por Raios X/veterinária
16.
PLoS One ; 16(2): e0246017, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33566809

RESUMO

OBJECTIVES: Although several self-reported questionnaire-based studies have found an association between smoking and moderately increased albuminuria, this result remains controversial. We investigated whether moderately increased albuminuria was associated with smoking status, verified by urinary cotinine (an objective biomarker of tobacco exposure), using population-based, nationally representative data. METHODS: This study included 2059 participants aged ≥ 50 years from the 2014 Korean National Health and Nutrition Examination Survey. Individuals with a urinary cotinine level ≥ 50 ng/mL were identified as cotinine-verified smokers. Moderately increased albuminuria was defined as a urine albumin-to-creatinine ratio ranging between ≥ 30 mg/g and < 300 mg/g. Multivariable logistic regression was used to evaluate the association between cotinine-verified smoking status and moderately increased albuminuria. RESULTS: Among the study participants, 16.9% were cotinine-verified smokers, 84.8% of whom were men. After adjustment for multiple covariates, cotinine-verified smokers showed a significant positive association with moderately increased albuminuria (adjusted odds ratio: 4.37, 95% confidence interval: 1.63-11.71) compared with cotinine-verified non-smokers. The association between urinary cotinine and moderately increased albuminuria did not differ with age, sex, obesity, or comorbidities (P-value for interaction > 0.05 in all cases). CONCLUSION: This large-scale observational study showed that cotinine-verified smoking is associated with moderately increased albuminuria in the Korean middle-aged and older general population, suggesting that smoking must be strictly controlled to reduce the risk of moderately increased albuminuria.


Assuntos
Albuminúria/complicações , Cotinina/urina , Fumar/epidemiologia , Fumar/urina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , República da Coreia/epidemiologia
17.
Vet Sci ; 9(1)2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-35051087

RESUMO

A 7-year-old castrated male Labrador retriever was referred for evaluation of progressive hind limb paresis of 4 weeks' duration. On computed tomography and magnetic resonance imaging examination, masses were found in several regions including the lung, right kidney, and peritoneum. Additionally, an extradural mass at the region of T13-L1 was identified, which is assumed to related to the chief complaint, progressive hind limb paresis. With the consent of the owner, a dorsal laminectomy was performed to remove the mass and surrounding tissues for the palliation of the hind limb paresis. Hematoxylin and eosin staining and immunohistochemical examination revealed the mass to be consistent with an undifferentiated (high-grade) pleomorphic sarcoma. The patient presented with recurrence of the hind limb paresis, respiratory discomfort, and urinary incontinence. The owner declined treatment and the dog was euthanized. Systemic metastasis was confirmed on postmortem microscopic examination. To the authors' knowledge, this is the first report describing multiple undifferentiated high-grade pleomorphic sarcoma with extradural involvement developing into the vertebral canal through the intervertebral space, resulting in spinal damage, in a dog.

18.
Front Physiol ; 11: 749, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32760285

RESUMO

Alcohol consumption leads to the dysfunction of multiple organs including liver, heart, and skeletal muscle. Alcohol effects on insulin resistance in liver are well evidenced, whereas its effects in skeletal muscle remain controversial. Emerging evidence indicates that alcohol promotes adipose tissue dysfunction, which may induce organ dysregulation. We show that consumption of ethanol (EtOH) reduces the activation of 5'AMP-activated protein kinase (AMPK) and mammalian target of rapamycin (mTOR) as well as the protein of carnitine palmitoyltransferase 1 (CPT1) and glucose transporter type 4 (GLUT4) in C2C12 myotube. We observed that chronic EtOH consumption increases free fatty acid levels in plasma and triglyceride (TG) accumulation in skeletal muscle and that these increases induce insulin resistance and decrease glucose uptake. Hence, ethanol dysregulates metabolic factors and induces TG accumulation. We found peroxisome proliferator-activated receptor ß/δ (PPARδ) activation recovers AMPK activation and increases carnitine-acylcarnitine translocase (CACT) protein. These effects may contribute to enhance mitochondrial activation via uncoupling protein 3 (UCP3) when fatty acids are used as a substrate, thus reduces EtOH-induced increases in TG levels in skeletal muscle. In addition, PPARδ activation recovered EtOH-induced loss of protein kinase B (AKT) phosphorylation at serine 473 via rapamycin-insensitive companion of mammalian target of rapamycin (Rictor) activation. Importantly, PPARδ activation enhanced mitochondrial uncoupling via UCP3. Taken together, the study shows PPARδ enhances fatty acid utilization and uncoupled respiration via UCP3 and protects against EtOH-induced lipotoxicity and insulin resistance in skeletal muscle.

19.
Sci Rep ; 10(1): 7527, 2020 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-32371928

RESUMO

Programmed, reshaping hydrogel architectures were fabricated from sugar/hydrogel inks via a three-dimensional printing method involving a stimuli-responsive polymer. We developed a new hydrogel ink composed of monomers (acrylamide [AAm]) and N-isopropylacrylamide [NIPAAm]), and sugar (mixture of glucose and sucrose) as a pore-generator, enabling to improve printability by increasing the ink's viscoelastic properties and induce the formation of macropores in the hydrogel architectures. This study demonstrated that creating macropores in such architectures enables rapid responses to stimuli that can facilitate four-dimensional printing. We printed bilayer structures from monomer inks to which we had added sugar, and we exposed them to processes that cross-linked the monomers and leached out the sugar to create macropores. In comparison with a conventional poly(N-isopropylacrylamide) hydrogel, the macroporous hydrogels prepared using polymerization in the presence of a high concentration of sugar showed higher swelling ratios and exhibited much faster response rates to temperature changes. We used rheometry and scanning electron microscopy to characterize the properties of these inks and hydrogels. The results suggest that this method may provide a readily available route to the rapid design and fabrication of shape-morphing hydrogel architectures with potential application in soft robotics, hydrogel actuators, and tissue engineering.

20.
PLoS One ; 15(4): e0231475, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32330139

RESUMO

The threat of arsenic contamination to public health, particularly in developing countries, has become a serious problem. Millions of people in their daily lives are still highly dependent on groundwater containing high levels of arsenic, which causes excessive exposure to this toxic element, due to the high cost and lack of water-treatment infrastructures. Therefore, a technique for large-scale treatment of water in rural areas to remove arsenic is needed and should be low-cost, be easily customized, and not rely on electrical power. In this study, in an effort to fulfill those requirements, we introduce a three-dimensional (3D), printed water-filtration system for arsenic removal. Three-dimensional printing can provide a compact, customized filtration system that can fulfill the above-mentioned requirements and that can be made from plastic materials, which are abundant. Armed with the versatility of 3D printing, we were able to design the internal surface areas of filters, after which we modified the surfaces of the 3D, printed filters by using iron (III) oxide as an adsorbent for arsenite. We investigated the effects of the controlled surface area on the flow rate and the deposition of the adsorbent, which are directly related to the adsorption of arsenic. We conducted isotherm studies to quantify the adsorption of arsenic on our 3D, printed filtration system.


Assuntos
Arsênio/química , Arsenitos/química , Filtração/métodos , Poluentes Químicos da Água/química , Purificação da Água/métodos , Água/química , Adsorção , Água Subterrânea/química , Ferro/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...